Electrically driven centrifugal pump 12 VDC or 18 VDC with CAS battery system for diesel, heating oil, AdBlue® urea solution and water as a submersible pump
The centrifugal pump with DC motor is intended for pumping the following liquids in compliance with the operating conditions specified in section 3.3:
Liquids with flash point > 55 °C and viscosity < 20 cSt, e.g.
- diesel fuel
- biodiesel
- EL heating oil
- Urea solution AUS 32 (AdBlue®)
- water
Any other or additional use is not intended.
Technical data:
Pump 12 VDC Pump 18 VDC
Voltage: 12 VDC +/- 10% 18 VDC +/- 10%
Fuse: 25 A -
Power: 220 W 220 W
Current consumption in normal operation: 16 A 12 A
Current consumption with closed dispensing valve: 18 A 13.5 A
Protection class: IP 68 IP 68
Power supply: via battery or power supply unit with safety transformer via CAS battery
Hydraulic data
(with water, 20°C)
Delivery pressure: max. 1.1 bar
Zero flow rate: 40 l/min
Delivery rate under nominal conditions: approx. 25 l/min
Operating conditions
Temperature range: - 20 °C to + 60 °C
Dimensions and weight
Diameter: 56 mm
Length: 185 mm
Weight: 0.65 k