Hydraulic program
All Products
O-ring set for connecting DVS directional control valves. Consisting of 3 pieces of O-rings for 2-way valves and 6 pieces of O-rings for 3-way valves.
Aluminum oil air cooler in panel construction. Maximum operating pressure 26 bar, protection class IP68.Oil coolers are used in continuous operation of hydraulic systems to cool the hydraulic oil. However, oil coolers are primarily installed on systems that have been subsequently equipped with additional hydraulic consumers. In many cases, the tank contents are not increased during these conversion work and this increases the circulation and temperature of the oil in the hydraulic system. The optimal operating temperature of a hydraulic system is between 50-60C. If the temperature increases too much, the excess heat must be dissipated via an oil/air cooler.In order to determine the size of the oil cooler, we need some data from you for the calculation:- Gear pump or control pump- Pump delivery rate in L/min- Tank capacity in L (if known)- Oil pressure in the hydraulic system in bar- Ambient temperature in C- Oil temperature of the hydraulic system in C - Connection voltage in VWe will be happy to calculate the oil cooler you need and look forward to your inquiry.
Aluminium-Ölluftkühler in Plattenbauweise. Maximaler Betriebsdruck 26 bar, Schutzart IP68.Ölkühler werden bei Dauerbetrieb von hydraulischen Anlagen zur Abkühlung des Hydrauliköls eingesetzt. Vorwiegend werden Ölkühler jedoch auf solchen Anlagen montiert, die nachträglich mit weiteren hydraulischen Verbrauchern ausgerüstet wurden. Bei diesen Umbauarbeiten wird in vielen Fällen der Tankinhalt nicht vergrößert und dadurch erhöht sich der Umlauf und die Temperatur des Öles im Hydrauliksystem. Die optimale Betriebstemperatur einer Hydraulikanlage liegt zwischen 50-60°C. Erhöht sich die Temperatur zu stark, muss die überschüssige Wämemenge über einen ÖL/Luftkühler abgeführt werden.Um die Größe des Ölkühlers festlegen zu können, benötigen wir für die Berechnung einige Daten von Ihnen:- Zahnradpumpe oder Regelpumpe- Fördermenge der Pumpe in L/min- Tankinhalt in L (wenn bekannt)- Öldruck im Hydrauliksystem in bar- Umgebungstemperatur in °C- Öltemperatur der Hydraulikanlage in °C- Anschlussspannung in VWir berechnen gerne für Sie den benötigten Ölkühler und freuen uns auf Ihre Anfrage
Aluminum oil air cooler, max. operating pressure 26 bar, protection class IP 68. World's first flexible mounting and connection system for oil coolers. The hydraulic connection direction can be freely selected for each connection with 3 directions and the flow direction in the cooler can be changed. The oil flow direction can be described as both "~U-flow"~ as well as with "~diagonal flow"~ can be realized without special parts!Delivery without connections.
The GT series oil coolers are a fully assembled cooler package consisting of an oil air cooler, fan control with sensor, connections, vibration dampers and protective housing.The temperature is controlled via an electronic control in conjunction with a temperature sensor. Depending on the oil temperature, this fan control ensures the optimal fan speed and a smooth start-up of the fan. This reduces noise and increases the service life of the fan unit.The protective housing is a stable frame with a metal protective grille in front of the cooling element. The cooler is mounted on the special asa vibration dampers in the protective frame to prevent vibrations.Aluminum oil air cooler, max. operating pressure 26 bar, protection class IP68.
The GT series oil coolers are a fully assembled cooler package consisting of an oil air cooler, fan control with sensor, connections, vibration dampers and protective housing.The temperature is controlled via an electronic control in conjunction with a temperature sensor. Depending on the oil temperature, this fan control ensures the optimal fan speed and a smooth start-up of the fan. This reduces noise and increases the service life of the fan unit.The protective housing is a stable frame with a metal protective grille in front of the cooling element. The cooler is mounted on the special asa vibration dampers in the protective frame to prevent vibrations. Aluminium oil air cooler, max. operating pressure 26 bar, protection class IP68.
The oil level indicators or level indicators made of plastic are suitable for checking the oil level in tanks and hydraulic systems. A metal housing protects the indicators against external mechanical stress.The polyamide material used has high mechanical strength and resistance to oil, lubricants, solvents, gasoline and most chemicals.The maximum operating temperature is 100C.
The oil level indicators or level indicators made of plastic are suitable for checking the oil level in tanks and hydraulic systems. A metal housing protects the indicators against external mechanical stress.The polyamide material used has high mechanical strength and resistance to oil, lubricants, solvents, gasoline and most chemicals.The maximum operating temperature is 100C.
The plastic oil level indicators or level indicators are suitable for checking the oil level in tanks and hydraulic systems.The polyamide material used has high mechanical strength and resistance to oil, lubricants, solvents, gasoline and most chemicals.The maximum operating temperature is 100C.
When machines and devices are switched off, the hydraulic lines are often under residual pressure or, for example, pressure has built up due to heating due to solar radiation. Coupling to the tractor hydraulics is then difficult or completely impossible. The hydraulic connector is then hit against a solid object so that the valve opens and the pressure is reduced. This causes the hydraulic oil to spray in all directions and hydraulic oil also enters the ground. In the long run, the coupling nipple at the front of the plug is also damaged.With the oil pressure drain pliers, the excess pressure in the hydraulic line at the plug is controlled, released safely and in an environmentally friendly manner. There are no more spilled workplaces and oily clothes!
Complete with return filter, filler neck with pressure relief valve 0.35 bar, oil level indicator with temperature display and suction connection with shut-off valve. A 1/4? internal thread is provided for the ventilation in order to screw in a ventilation filter, e.g. Faie No. 12833, or to be able to attach a ventilation line. The inside of the tank is blank (not painted).Filter connection: G1" IT
The oil tank is supplied complete with a lid and lid seal. A drain with a 1/2" BSP internal thread is fitted on the side to allow the tank to be completely emptied.The steel tank is primed with anti-rust paint.
Advantages:Accurate operating hours recording, speed display from 100 rpmManipulation-proofEasy installation, robust, reliable constructionNo additional costs due to battery operation Power supply necessary, long battery life Cost-effective purchase Function: A sensor disk with an integrated magnet is mounted on the PTO connecting shaft on the implement. At a short distance from this there is an inductive sensor that records the rotational movements and forwards them to the counting device. The counting process/time measurement only begins when the idle speed of the PTO shaft has exceeded 100 rpm. The counting device is equipped with a digital hour and minute display. The switch between operating hours display and speed display occurs automatically. As soon as the revolutions of 100 rpm are reached, the speed is displayed. When the drive shaft subsequently comes to a standstill, the display switches to the operating hours.Easy installation:The encoder disc is pushed over the standardized PTO shaft connecting piece and secured with a locking screw. An inductive sensor records the speed and passes it on to the operating hours counter. The cable length from the sensor to the display is 1.5m.
For bends up to 90, for bendable steel and stainless steel pipes. Up to a maximum wall thickness of 1.5 mm.
BG 3. Serves to accommodate the uncoupled plug. Mounting thread M18x1.5mm.
Male to fixed part with G1/2" internal thread
6-pin for electrical cable entry on the tractor side.
Sleeve, external thread,push-pull design
Plug, external thread,push-pull design.
Sleeve, external thread,push-pull design.
Plug, external thread,push-pull design.
Sleeve, external thread, light series with bulkhead thread,push-pull design.
Unser Produktleiter
Werner Meixner
€10 voucher.
If you sign up for our newsletter.
You will receive €10 for free with your next purchase.
